Description
Ghost rid-off Column impurity trapping column(Ghost Traps/Ghost Columns/Ghost Hunter Trap Column/ Ghost Trap DS/Ghost-Sniper Column/ghost trapper column Mobile phase cleaner for HPLC)
Impurity trapping column can effectively remove impurities in mobile phase (”Ghost” peaks during gradien )and completely eliminate ghost peaks, thus greatly shortening the time of method verification and analysis of trace and trace substances.
Especially for drug analysis and research personnel, the Ghost rid-off Column impurity trapping column is your essential artifact to eliminate ghost peaks.
Installation method:
The ghost peak removal column is stored in pure methanol. Before use, it should be washed with pure methanol at a flow rate of 1.0ml/min for 20 minutes. (Note: do not connect the chromatographic column and detector for washing) After washing, remove the column, and connect it between the mixer and the sampler according to the installation position shown above.
The main feature of Ghost rid-off Column impurity trapping column is that it can remove impurities from solvents, including organic solvents. In the gradient analysis of reversed-phase chromatography, installing a small column between the gradient mixer and the automatic sampler can not only remove impurities in the mobile phase, but also effectively remove impurities in the pipeline and mixer.
Service life:
After 600 analyses, there is still no ghost peak. The experimental results show that the trapping column can stably adsorb impurities and has sufficient loading capacity for multiple analyses.
Description:
The actual service life of the product varies according to the analysis conditions, such as the different mobile phases used, and not all impurities can be removed.
After the product is connected to the junction of gradient mixer or pump, there will be a delay volume equal to the column volume in gradient analysis, and almost all brands of liquid instruments can use this product.
When mass spectrometry is used as a detector, the product may be slightly dissolved and cause baseline noise. If the ion pair reagent is used in the analysis, the product may adsorb the ion pair reagent and affect the retention time or peak type of the components.
Before connecting the analytical column, be sure to thoroughly flush the pipeline connecting the product with mobile phase (close to the final concentration in gradient analysis).
| Item number (P/N) | describe | Pressure-resistant/adaptive instrument | Column volume |
| 100001-001 | Keenfine® Ghost rid-off columnI 50×4.6mm | 400 Bar/HPLC | 630μL |
| 100001-002 | Keenfine® Ghost rid-off columnI 50×4.0mm | 400 Bar/HPLC | 480μL |
| 100002-001 | Keenfine® Ghost rid-off columnII 30×4.0mm | 400 Bar/HPLC | 280μL |
| 100002-002 | Keenfine® Ghost rid-off columnII 50×2.1mm | 1000 Bar/UHPLC | 130μL |
| 100002-003 | Keenfine® Ghost rid-off columnII 30×2.1mm | 1000 Bar/UHPLC | 80μL |
Contact information
Manufacturer: Guangzhou Qifeng Biotechnology Co., Ltd.